Vibration Transducer Calibration System 8210

Applicable Objects

▪Working piezoelectric acceleration transducer, velocity transducer and vibrometer while produced, maintained and employed 

▪Various types of acceleration, velocity transducer and vibrometer, such as voltage type, charge type, IEPE type, TEDS type and so on.

Standard

▪ISO 16063-21:2003 Vibration and Shock Transducer Calibration Method

System Features

▪Calibrate accurately all kinds of acceleration transducer, velocity transducer and vibrometer, including voltage type, charge type, IEPE, TEDS, etc. 

▪Frequency range is 2Hz-20kHz, support point-by-point comparison calibration, swept sine calibration, random excitation and impact excitation methods, etc; 

▪High precision and dynamic range, system uncertainty: <1% (160Hz, 100 m/s2)

▪At the end of calibration, it will automatically generate a detailed report, including sensitivity, linearity and amplitude and frequency response curve; all data will be input database, compiling refers to ISO17025.

▪Substitution calibration option prolongs the service life of standard transducer. 

▪TEDS transducer support, and results wrote in it.

Calibration Items

▪Sensitivity Calibration: frequency range default160Hz, acceleration default 10m/s2 

▪Frequency Response  

 ▫Swept Sine: Breakpoint tabular form defined the          sweep range and reference acceleration value; User    defined sweep method (logarithmic or linear), sweep     speed and time.  

 ▫Step Sine: Tabular form defined at least 10                  frequency points and its reference acceleration,          max.4096 discrete points, frequency points                  according to 1/3 octave or 1/1 octave.  

 ▫Random Calibration(FFT):Breakpoint tabular        form defined random profile; User defined RMS            value, analysis lines and calibration time. 

▪Amplitude Linearity: The curve is frequency VS   acceleration which reflects the frequency VS sensitivity. Tabular form defined the measurement frequency points. 

▪Transverse Sensitivity Calibration: The transverse sensitivity is the accelerometer output sensitivity when acceleration is applied at its geometrical right angle.

Standard Shaker

Model

512-A

Exciting Force(N)(kgf)

49(5)

Frequency Range (Hz)

2 to 20k

Maximum Acceleration(m/s2)(g)

376.9(38.4)

Maximum Displacement(mm)

7

Maximum Velocity(m/s)

1.14

Armature Mass(kg)

0.13

Armature Material

Magnesium

Stiffness(N/mm)

12

Cooling

Natural

Mass(kg)

9.5

Matched Power Amplifier

371-A

Power Amplifier

Model

371-A

Apparent Power(VA)

110

Output Voltage(Vrms)

20

Output Current(Arms)

5.5

Frequency Range(Hz)

2-30K

Input Impedance(Ω)

10K

Input Voltage(Vrms)

1

Matching Impedance

3.64

Load Impedance

1.82

S/N(dB)

80

Distortion(%)

0.5

Meter(Arms)

7.5

Input Connector

BNC 3.2

Input to Blower(VA)

-

Protector

Overcurrent Transistor temperature Overload

Input Power

AC100V 50/60Hz

Maximum Power Consumption(VA)

300

Dimensions(mm)

480WX149HX350D

Mass(kg)

12.5 or app.

Operation Environment

Temperature range: 0℃ to 40 ℃ Humidity range: 20 to 85%RH without dewdrop