High Current Rectifier(HRC)ZHS-20000A/670V Structure Feature & Advantages

▲ Adopted cophase counter parallel connection Rectification,wihich can increase the power factor and reduce power loss

▲ Three-phase bridge rectification,which has the characteristics of reliability,stability,and low losses

▲ Adopted aluminum frame and glass antimagnetic cabinet, which suit for monitor and maintenance

▲ Power is scalable

▲ Can be maintained with electricity.

▲ With Low noise 

▲ Easy to operate 

▲ Superiority of Ture Rdundancy technique

▲Over / low Voltage protection    

▲Over / low current protection   

▲Over / lack water protection        

▲Over temperature protection

▲Fast fuse protection      

▲Phase protection  



Technical Parameters

Model

ZHS-20000A/670V

Efficiency

≥99.5%

Input Voltage

AC380V

Rated Voltage

DC670V

Input Current

AC85A

Rated Current

DC20000A

Range of Regulation

 

On-load Voltage + Switch  Regulation: 15%-105% Udn

Notes forOrder

 

Input Voltage

AC300V-330KV

Optional

Frequency

40-60Hz

Optional

Current Regalation


Optional

Voltage Regulation


Optional

Rated Current


Optional

Rated Voltage


Optional

Cooling Mothed

Water,Air,natural or Forced

Draft Cooling

Optional

Digest of High Current Rectifier(HCR)technical documents.

Part two of Rectifier transformer Installation and Operating Instruction



  6、Assembly test and installation

    6.1 If current transformer is mounted,  be open circuit operation is not permitted on secondary side.

    6.2 to ensure the accurary of thermometer, the mercury thermometer pocket shall be filled with oil.

    6.3 The determination of oil surface temperature shall depend on oil level indication of conservator, the ambient temperature at that circumstance shall be set to be+15℃.

    6.4 Transformer oil shall not be mixed. If so, the comparison test shall be conducted. And only when the results meets operation requirements, it’s allowed to do so.

    6.5 the following tests shall be conducted ahead of the rectifer transformer putting into service.

    6.5.1 the DC resistance value of windings shall conform to data brought forth in technical documents for delivery. DC resistance value of LV winding is low, better to use step-down testing method.

    6.5.2 Voltage ratio to be meausured on each tapping position

    6.5.3 insulation resistance (including branches of LV side) obsorption ratio and loss tangent shall be measured.

    6.5.4 Insulation test shall be conducted, whose applied voltage value shall be lower than the data in test report. Refer to Transformer Operation Regulation.

    6.5.5 No-load test

    6.5.6 OLTC and forced oil cooling system shall be tested according to each operation manual.

    6.6 during installation of rectifier transformer, attention shall be paid to sealing condition of secondary terminals, esp. The secondary terminals can not bear machnical stress.

    6.7 for rectifier transformer with saturable reactor, the transformer shall be placed on a solid base to avoid resonance vibration.

    6.8 to mount rating plate, valves etc. on HV side for convenient sake.

    7 attentions during operation

    7.1 transformer oil shall be prosodically examined to check oil quality and any bubbles exists.

    7.2 the ascending flanged base shall be air exhausted periodically.

    7.3 the inspection of transformer under service shall be conducted in power failure. If to exam in transformer

    8 All clauses unmentioned shall be as per Operation Regulation on Power transformer.

Please give us the follows technical information before order:

1  A.C. INPUT

• A.C: rated voltage

• Phases

• Frequency

2  D.C. OUTPUT

• Rated D.C. voltage

• Rated D.C. current

• D.C. voltage fine control range (thyristors)

• D.C: current control range

• Accuracy of current fine control

• Pulse number

• Ripple

 

The High Current Rectifiers listed on this website is customized, just for your reference. If you have any specific demands,please tell us the parameters in details. We’ll be more than happy to work with you to meet your exact requirements.

The main parameters of our Thyristor / Diode High Current Rectifiers for Industrial Applications:

A)Voltage Specification:  5V - 3000V

B)  Current Specification:  300A - 240000A

C)  Output Current Adjusting Range: 0 - 1000A

 

The expert teams with 20 years experience can supply equipment design,manufacture, upgrading and after sales service. It’s quality management system meets the requirement of the ISO9001:2008 standard. The Technical level of main equpment is ten years ahead in China,and the control system is twenty years ahead at home and abroad.